Skip to main content
U.S. flag

This is an original und secure website

Pulmonary Vascular Resistance Calculator

mmHg
mmHg
L/min

The resistance offered by the vasculature of the lungs is known as the pulmonary vascular resistance (PVR). By entering the Mean Pulmonary Arterial Pressure, Capillary Wedge Pressure and cardiac output, PVR due to the vasculature of lungs can be calculated.

Formula

Pulmonary Vascular Resistance(dyne*sec/cm5) = ( 80 * (PAP – PCW) / C.O )
  • PA = pulmonary artery pressure
  • PCW = pulmonary Cap Wedge pressure
  • C.O. = Cardiac Output

Calculation of Pulmonary vascular resistance (PVR) due to the vasculature of lungs is made easier. Free online medical calculator.

PVR explained

This pulmonary vascular resistance (PVR) calculator estimates vascular resistance in the pulmonary circulation based on arterial and atrial pressure difference and pulmonary blood flow.

There are three variables to be specified, as described in the table below:

Variable Measurement units Description Normal values
Mean Pulmonary Arterial Pressure mmHg, cmH2O, kPa, atm or psi Input to the pulmonary blood circuit. 10 – 20 mmHg
Left Atrial Pressure mmHg, cmH2O, kPa, atm or psi Output of the pulmonary circuit at the place where blood is transferred to the left atrium. 6 – 12 mmHg
Pulmonary flow L/min, mL/min In most cases, pulmonary flow is equivalent to cardiac output. 4 – 8 L/min

Vascular resistance is measured in dynes-sec/cm5, but can also be expressed in mmHg-min/L, measurement known as hybrid reference units or Wood units.

Normal PVR is between 20 and 130 dynes-sec/cm5.

The PVR formula is:

PVR measured in dynes-sec/cm5 = 80 x (Mean Pulmonary Arterial Pressure in mmHg – Left Atrial Pressure in mmHg) / Pulmonary Flow in L/min

There is also a simplified formula that provides PVR in mmHg-min/L:

PVR measured in mmHg-min/L = (Mean Pulmonary Arterial Pressure in mmHg – Left Atrial Pressure in mmHg) / Pulmonary Flow in L/min.

About pulmonary vascular resistance

PVR is a characteristic of the pulmonary circulation and represents the difference of pressure across the pulmonary circuit, divided by the rate of blood flow going through it. This definition and the usual calculation have been explored above.

The main physical determinants of resistance to blood flow in a blood vessel are:

  • Vessel length (L);
  • Vessel radius or circumference (r);
  • Blood viscosity (η).

Vessel radius controls:

  • Vasoconstriction (decrease in blood vessel diameter and increase in PVR);
  • Vasodilation (increase in blood vessel diameter and decrease in PVR).

PVR is influenced by the tone in the small resistance arterioles (vessels with diameters between 100 and 450 µm) and by the resistance in pre-capillary arterioles (even smaller diameters).

PVR also depends on lung volume and was determined to be at its lowest at functional residual capacity (FRC).

Causes of high PVR or pulmonary hypertension include:

  • Pulmonary vascular disease;
  • Pulmonary embolism;
  • Pulmonary vasculitis;
  • Hypoxia.

Lower than normal PVR is most commonly caused by dysfunction in one of the following: calcium channel blockers, delivery of O2, isoproterenol or aminophylline.

Example of a PVR calculation

When:

  • Mean Pulmonary Arterial Pressure = 16 mmHg;
  • Left Atrial Pressure = 13 mmHg;
  • Pulmonary flow, cardiac output = 5.5 L/min.

The pulmonary vascular resistance = 80 x (16 – 13) / 5.5 = 43.64 dynes-sec/cm5.

References

  1. Barratt-Boyes BG, Wood EH. Cardiac output and related measurements and pressure values in the right heart and associated vessels, together with an analysis of the hemo-dynamic response to the inhalation of high oxygen mixtures in healthy subjects. J Lab Clin Med. 1958; 51(1):72-90.
  2. Baim D. (2006) Grossman's Cardiac Catheterization, Angiography, and Intervention. Lipincott Williams & Wilkins 7th ed.
  3. Skimming JW, Cassin S, Nichols WW. Special Article: Calculating Vascular Resistances. Clin. Cardiol. 1997; 20, 805-808.

Importend Notes and Disclaimer

 

Caveats and Recommendations: This calculator is NOT intended to diagnose illness or be used as a substitute for medical advice or treatment. Some models provide predictive outcomes which may not be accurate. Please consult a medical professional for any medical treatment or diagnosis advice.

 

Note: This calculator is presented for your own personal use and is to be used as a guide only. Medical and other decisions should NOT be based on the results of this calculator. Although this calculator has been tested, we cannot guarantee the accuracy of its calculations or results.

 

Disclaimer: This calculator is provided without warranty and CANNOT be used to diagnose or treat any disease or condition.

In 51 U.S. states are published

6008 Companies
1559 Counties
3438 Cities

The 5 newest Companies

Frank's Automotive

102 Cory Ave, Prescott, AZ 86303

LKC Automotive & Towing

184 E State Rd, Pleasant Grove, UT 84062

Bill's Auto Repair

339 NJ-31, Flemington, NJ 08822

Garcia Trinity Auto Inspection

6518 Airport Blvd, Houston, TX 77048

Raspi's British Imports

125 A Industry Ln #1, Forest Hill, MD 21050

Other Companies

City Automotive Services

1515 Redwood Ave # 3, Grants Pass, OR 97527

Gunpowder Garage

8660 Cherry Ln # 52, Laurel, MD 20707

Performance Kent Automotive

173 Osceola Ave, Tallmadge, OH 44278

Gil's Auto Medic

950 US-90, Bonifay, FL 32425

Cruisin- Gold

195 Coastal Ln., West Melbourne, FL 32904